Hexachlorocyclotriphosphazene has many properties. It is difficult for non professionals to understand the density of the product, so they know less about the bulk density. The following will focus on explaining the bulk density test knowledge of the product for you:
1. Appliance: one 100ml or 250ml measuring cylinder.
2. One balance with weighing range of 500g (accuracy ± 0.5g).
3. A calculator.
4. A funnel.
Test method:
Add Hexachlorocyclotriphosphazene evenly into the measuring cylinder with a funnel to the 100ml scale. The added plane shall be level with the 100ml scale line, and then pour the expanded perlite in the measuring cylinder into the balance to weigh the value M. The calculation formula of loose bulk density is: ρ (density) = m (mass) / V (volume). The unit of this calculation result is g / cm3. If it needs to be converted into kg / m3, multiply it by 1000.
Particle size test method (applicable to Hexachlorocyclotriphosphazene produced from 20-30 mesh perlite ore):
The Hexachlorocyclotriphosphazene shall have relatively large particles, and there are no excessive requirements for the substances on the screen. It is only necessary to test that the substances under the screen do not exceed the standard. The standard requirements for the substances under the screen are - 80 mesh sieve (national standard sieve) < 10%.
The test method is to use an 80 mesh national standard circular analysis screen, add 100g Hexachlorocyclotriphosphazene into the screen, put the circular analysis screen added with the product into the flapping screen for 5 minutes, take it out, and weigh the percentage of the content under the screen in the total mass. After such a good grasp, I believe it will bring you help in use.